What’s in the box?
Accessia Reader
Bezel removal tool
What you’ll need
2 x 3.5mm diameter (no. 6) panhead screws and wall anchors suitable for the wall surface the Reader will be mounted on
5-way terminal block with suitable tool for 24AWG wire connection
Bezel removal tool (supplied)
120 Ohm +/- 1% termination resistor (depending on topology)
Mounting guide
Before you start
Make sure the wall you want to mount the Reader on is flat and vertical
Choose a good position that is easy for all users to access, including those with limited mobility
Make sure there is a hole in the wall behind the Reader which you can pass the integrated cable through
Avoid mounting the Reader directly onto a metallic surface
How to mount the Reader
Remove the bezel. Insert the removal tool into the two holes at the bottom of the Reader. Push the tool in until the clips at the lower end of the bezel release and lift. Unhook the upper end of the bezel and remove it from the Reader (Figure 1)
Remove the mounting bracket from the back of the Reader by sliding it downwards (Figure 2)


Secure the mounting bracket to the wall using fixings appropriate for the wall surface. Make sure that the that the hole in the wall for the integrated cable and the exit point for the cable from the Reader are lined up when positioning the mounting bracket (Figure 3)

Pass the integrated cable though the mounting bracket and the wall and then hook the Reader onto the mounting bracket. Make sure the Reader is fully attached to the mounting bracket
Hook the top edge of the bezel over the top of the Reader and press the lower end of the bezel until it clicks securely into place
Wiring guide
The Reader must be connected to an Accessia Hub. For connections and topologies, check the AI Security Hub installation guide and Figure 4 below
The Reader must be connected using shielded twisted pair cable, for example Belden 8723. Connect the shield to the drain wire in the Reader’s integrated cable
The RS-485 twisted pair must be terminated at both ends with a 120 Ohm +/- 1% resistor. For details, check the AI Security Hub installation guide
Make sure that the terminal block and all wiring is inaccessible to unauthorized personnel

Maximum cable lengths:
22 AWG: 250 feet / 76 meters
20 AWG: 330 feet / 100 meters
18 AWG: 500 feet / 152 meters
Information
Reader supported credentials
NFC - MIFARE DESFire EV2 and EV3
BLE - Accessia for mobile and SDKs
UWB - Accessia for mobile and SDKs
How to clean
When necessary, clean the Reader with a soft damp cloth. Do not use any solvents or abrasive materials
Compatibility
Readers are only compatible with Accessia Hubs
Software version
Reader software is automatically updated when necessary by the Hub. To check the current software version, check Accessia Installer app or Accessia Portal
Operating conditions
Power input: 8 to 12VDC, 2 Watts maximum
Operating temperature range: -31 to 150ºF / -35 to +66ºC
Humidity: 20 - 90% RH non-condensing
Ingress protection rating: IP65
Impact protection rating: IK07
Compliance
Compliance Model RDR01A