AI Security Hub installation
Getting started with AI Security Hub
Document Number 490-0001-01
Revision 05 – 17 January 2025
What’s in the box?
Accessia Hub
Hub key
What you’ll need
Equipment
4 x 5mm diameter (no. 10) panhead screws and wall anchors suitable for the wall surface the Hub will be mounted on
Tools for mounting, wiring, and knocking out and deburring cable apertures
Appropriately sized conduit and bushes for all wiring external to the Hub
3mm flat-head screwdriver for wiring terminals
Network and AC mains connection
The Hub requires a connection to the local area network using 100BaseT Ethernet. This local area network must permit HTTPS connections to the internet. The Hub will automatically use this connection to establish a secure connection to Accessia’s cloud
Wiring guide
For the AC mains connection, see Connecting mains and battery power. Make sure that the AC mains is isolated before starting any wiring activities inside the Hub enclosure
All other wiring in the system is safety extra low voltage (SELV) and should not be connected to any voltage greater than 30 VDC. The wiring to the DC power input and battery connection terminals is already provided using 16AWG wire. For the remaining connections, use a wire gauge in the range 14 to 24 AWG, making sure that the wire gauge is suitable for the maximum current being conducted
The network connection must be made using Cat5 (or better) cable
3. Connecting a channel
The Hub supports up to four channels. For each channel, there are connections for:
Up to two OSDP Readers (including RS485 signal pair and 12VDC power supply)*
One lock
Two inputs with dual end-of-line (DEOL) monitoring support
Two groups of terminals are provided for the lock: wet and dry
*2 readers per channel coming soon
Also see: Channel output power guide
Additional information
Compatibility
Cloud: the Hub is only compatible with Accessia’s cloud
Readers: the Hub is compatible with OSDP Readers
Programming
Programming and configuration of the system can be done using either Accessia Installer app or the Portal
Software
System software is automatically updated when necessary by Accessia’s cloud. To check the current software version, check Accessia Installer app or Accessia Portal
Operating conditions
AC mains input: 100 – 240VAC 50/60Hz, 3A
Operating temperature range: 32°F ~ 120°F / 0 ~ 49oC
Humidity: 20 - 90% RH non-condensing
Compliance
Compliance Model CTL01A
FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation
UL294/UL293 Access control performance levels
Destructive attack: Level I (Local Level III for reader RDR01A)
Line security: Level II
Endurance: Level IV
Standby Power, 60W output: Level II
Standby Power, 24W output: Level III
Last updated