Channel inputs
The channel inputs can be used for request-to-exit (REX) buttons, door position sensors, or lock status sensors
Configure input functions using Accessia Installer app
The inputs should only be connected to isolated switch contacts – do not connect to a power supply
For end-of-line monitoring, use 2.2 kOhm +/- 1% resistors at the switch (Figure 1)

For optimum DEOL monitoring performance, keep the inputs isolated from each other. If it cannot be avoided, the two inputs on the same channel can share a common terminal. In this case, wire the two inputs as shown in Figure 2

Adjacent to the input terminals is a switchable 12VDC power output for peripheral devices. This can be used for a touch-free REX button or a door-left-open alarm. Configure its function in Accessia installer app
The labeling on the Hub shows the correct pin out for all these connections
Last updated